FEKABOX 110 sūknetavas tvertne bez sūkņa
FEKABOX 110 sūknetavas tvertne bez sūkņa
⬤ Out of stock
Shipping options
Store stock information
Sorry, not available at the moment
FEKABOX 110 sūknetavas tvertne bez sūkņa
General specs
- Grupa:kanalizācija
Specs
- Product code: 60164870
- Barcode: 8059893072979
- Brand: DAB
0 Reviews
Rating 0You must be logged in to leave a review
Product description
Automatic collection and lifting station for one pump, for waste water or rainwater in semi-basement rooms located below the level of the sewer system in residential building service.
It consist of a 110 liter polyethylene tank (eco-friendly because 100% recyclable). Cover complete with gasket.
It may contain liquids compatible with the EN 12050-2 standard. The station is designed for the use of a single automatic single-phase pump with float which must be ordered separately (without the control panel).
The pump installation kit, the cable gland for a single pump and the 2 "F x 1 x 1/4 M fitting for the installation of a Feka 600 are included.
The tank can be installed inside or outside a building, fixed to the floor and buried. It is not walkable or suitable for the passage of vehicles.
Type of pumped liquid: Waste water, sewage water
Liquid temperature: From 0°C to +50°C
Tank capacity and type of material: 110-liter in polyethylene
Possible type of installation: The tank can be installed inside or outside a building, fixed to the floor and buried. It is not walkable or suitable for the passage of vehicles.
FEKA VS 750 M - A 50 Hz 230 FEKABOX 110
Submersible centrifugal pump with liquid vortex cast steel impeller, suitable for pumping sewer water and waste water in general containing solids up to a maximum size of 50 mm.
Handle with insulating rubber cover. AISI 316 stainless steel drive shaft. Double mechanical seal with
intermediate oil chamber (atoxic oil), in carbon/alumina on the motor side and silicon carbide/silicon carbide on the pump side.
Stainless steel pump casing, seal cover, motor casing.
Dry, asynchronous, sealed and cooled by the pumped liquid. Rotor mounted on greased for-life ball bearings, oversized and selected to guarantee greater noise reduction and duration. Thermo-amperometric protection as standard for single-phase version, and the user’s responsibility for the three-phase version. Constantly active capacitor on the single-phase version.
Construction in accordance with the IEC 2-3 IEC 61-69 (EN 60335-2-41) standards.
- Motor protection class: IP 68.
- Insulation class: F.
- Continual running with liquid at 35 °C and pump completely submersible.
The single-phase version can be supplied with float for automatic function.
- Power supply cable: 10 mt of H07RN-F cable with Schuko plug for the single-phase version and 10 meters of H07RN-F cable for the three-phase version.
- Operating range: from 0 to 32 m3/h with head up to 14 mt.
- Pumped liquid: sewer water and waste water in general and non aggressive.
- Liquid temperature range: from 0°C to +35°C for household use (EN 60335-2-41),
from 0°C to +50°C for other uses.
- Maximum ambient temperature for pump running with submersible motor: +40°C.
- Maximum immersion depth: 7 mt.
- Installation: fixed or portable, vertical.
- Free Passage: 50 mm